SabikVertonA3000Zresin adalahsenyawa yang didasarkan pada resin Acrylonitrile Butadiene Styrene yang mengandung Anti-Static.
Bahan-bahan ini meliputi:
Properti Tipikal (1) | |||
Mekanis | Nilai | Satuan | Standar |
Tekanan tarik, yield | 30 | MPa | ASTM D 638 |
Tekanan tegangan, istirahat | 24 | MPa | ASTM D 638 |
Tekanan tarik, hasil | 3.5 | % | ASTM D 638 |
Tekanan tarik, putus | 52.1 | % | ASTM D 638 |
Tensile Modulus, 50 mm/min | 1370 | MPa | ASTM D 638 |
Modulus Flexural | 1370 | MPa | ASTM D 790 |
Tekanan tarik, yield | 36 | MPa | ISO 527 |
Tekanan tegangan, istirahat | 27 | MPa | ISO 527 |
Tekanan tarik, hasil | 3.5 | % | ISO 527 |
Tekanan tarik, putus | 50.1 | % | ISO 527 |
Modulus tarik, 1 mm/menit | 1580 | MPa | ISO 527 |
Tekanan Flexural | 45 | MPa | ISO 178 |
Modulus Flexural | 1600 | MPa | ISO 178 |
Dampak | Nilai | Satuan | Standar |
Izod Dampak, tidak diukir, 23°C | 1420 | J/m | ASTM D 4812 |
Izod Dampak, bertanduk, 23°C | 389 | J/m | ASTM D 256 |
Energi Dampak Instrumen @ puncak, 23°C | 39 | J | ASTM D 3763 |
Dampak Multiaxial | 35 | J | ISO 6603 |
Izod Impact, tidak diukir 80*10*4 +23°C | 148 | kJ/m2 | ISO 180/1U |
Izod Impact, bernotas 80*10*4 +23°C | 32 | kJ/m2 | ISO 180/1A |
Termal | Nilai | Satuan | Standar |
HDT, 0,45 MPa, 3,2 mm, tidak diiris | 86 | °C | ASTM D 648 |
HDT, 1,82 MPa, 3,2 mm, tidak diiris | 73 | °C | ASTM D 648 |
CTE, -40°C sampai 40°C, aliran | 1.28E-04 | 1/°C | ASTM E 831 |
CTE, -40°C sampai 40°C, xflow | 1.03E-04 | 1/°C | ASTM E 831 |
CTE, -40°C sampai 40°C, aliran | 1.27E-04 | 1/°C | ISO 11359-2 |
CTE, -40°C sampai 40°C, xflow | 1.03E-04 | 1/°C | ISO 11359-2 |
HDT/Bf, 0,45 MPa Flatw 80*10*4 sp=64mm | 91 | °C | ISO 75/Bf |
HDT/Af, 1,8 MPa Flatw 80*10*4 sp=64mm | 78 | °C | ISO 75/Af |
FISIK | Nilai | Satuan | Standar |
Kepadatan | 1.05 | g/cm3 | ASTM D 792 |
Penyerapan Kelembaban, 50% RH, 24 jam | 1.6 | % | ASTM D 570 |
Penyusutan jamur, aliran, 24 jam | 0.7 - 0.9 | % | ASTM D 955 |
Penyusutan jamur, xflow, 24 jam | 0.8 - 1 | % | ASTM D 955 |
Penyusutan jamur, aliran, 24 jam | 0.77 | % | ISO 294 |
Penyusutan jamur, xflow, 24 jam | 0.92 | % | ISO 294 |
Kepadatan | 1.05 | g/cm3 | ISO 1183 |
Listrik | Nilai | Satuan | Standar |
Resistensi Permukaan | 1.E+08 - 1.E+10 | Ohm | ASTM D 257 |
Sumber GMD, terakhir diperbarui:09/24/2008 |
Parameter | ||
Pencetakan Injeksi | Nilai | Satuan |
Suhu Pengeringan | 70 - 80 | °C |
Waktu Pengeringan | 4 | jam |
Kandungan Kelembaban Maksimal | 0.05 - 0.1 | % |
Suhu Peleburan | 200 - 210 | °C |
Suhu depan - Zona 3 | 205 - 215 | °C |
Tengah - Zona 2 Suhu | 195 - 205 | °C |
Bagian belakang - Zona 1 Suhu | 180 - 195 | °C |
Suhu Cetakan | 10 - 50 | °C |
Tekanan Belakang | 0.2 - 0.3 | MPa |
Kecepatan sekrup | 30 - 60 | rpm |
Sumber GMD, terakhir diperbarui:09/24/2008 |
Untuk informasi lebih lanjut silahkan download lembar data |
|
![]() |
S-Plastics Verton A3000Z.pdf |
Dapatkan Kutipan Terbaru
Sumber distribusi tingkat pertama di Cina Selatan Mengurangi biaya pengadaan, meningkatkan stabilitas pasokan, Membantu Anda menemukan bahan plastik rekayasa yang paling cocok
|